masthead prod
citotoxic_safety_cabinets-cytofast-elite
citotoxic_safety_cabinets-cytofast-elitecitotoxic_safety_cabinets-cytofast-elite-keyboardcitotoxic_safety_cabinets-cytofast-elite-2citotoxic_safety_cabinets-cytofast-elite-filters-replacementcitotoxic_safety_cabinets-cytofast-elite-piano-cfcitotoxic_safety_cabinets-cytofast-elite-standard-utilitiescitotoxic_safety_cabinets-cytofast-elite-v-shape-profile

CytoFAST Elite

CytoFAST Elite Cytotoxic Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards.

CytoFAST Elite are Cytotoxic Drug and Microbiological Safety Cabinets designed and built to performance requirements of the EN 12469:2000 and DIN 12980:2005-06 European Standards. They are triple HEPA filter technology cabinet, with 100% of the air filtered via the main H14 HEPA/ULPA filter directly below the work surface and then 70% of the air re-circulated via the recirculating H14 HEPA/ULPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust H14 HEPA/ULPA filter.

CytoFAST Elite have been designed to guarantee the product, personnel and environmental protection and they are primary suitable for applications such as: preparation and handling of cytotoxic drugs, preparation and manipulation of antineoplastic chemotherapeutics, preparation and manipulation of CMR drugs and any other agents likely to cause genetic alterations or synergetic activities with other materials.

Since CytoFAST Elite meet also EN 12469 as for Class II Biohazard cabinets, they can be adopted also for a wide range of disciplines in applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals.

CytoFastELiteThe ambient air is drawn in from the slots at the stainless-steel base of the front opening and it then passes through the H14 HEPA/ULPA filter bank below work surface, from where it is drawn up and blown into the plenum of the re-circulating and exhaust fan.

The “bio-dynamic sealing system” of the negative pressure plenum ensures that all contaminated particles are kept inside the system and are automatically drawn to the plenum or pressure chamber to be captured by the main re-circulating and exhaust H 14 HEPA/ULPA filters.

The fan system assures that no part of the cabinet comes ever under positive contaminated pressure to the laboratory, thus protecting and preserving the environment and operating personnel from exposure to cytotoxic drug, CMR compounds and agents of bio-contamination.

70% of the filtered air is re-circulated (after passing through a H14 HEPA/ULPA filter) in an air cleanliness in Class ISO 3, according to ISO 14644-1 laminar flow pattern downwards into the work chamber and the remaining 30% is exhausted to atmosphere through another H14 HEPA/ULPA filter.

Ergonomic Design: The angled sloping (7°) front stratified safety-glass sash provides optimum visibility of all objects placed in the interior workspace. The sash is electrically operated. Pressing the appropriate touch-sensitive keys will completely open or completely close down the sash. The standard sash-height opening during work is set to 200 mm. Alternative sash-height settings (250-160mm) by the factory are possible upon request. The whole front of the safety cabinet – which includes the sash mechanism – can also be opened upwards as it is hinged on the top – in order to allow easy access for complete and effective cleaning and decontamination.

Real Laminar AirFlow: Frontal screen 7° sloped as well as back side wall to convey in unidirectional pattern the air flow. As a consequence, the front and back panels are parallel one with the other and there is the real presence of Laminar AirFlow in the whole working area.

Innovative system of third bank H 14 HEPA/ULPA filtration beneath the working surface with increased space for operator’s knees and comfort (>480mm): the filters are conceived with the suitable size to be disposed in a standard 60lt waste bin according to the latest version of DIN 12980:2005-06 Standard. Bag-Out System: Safe and easy H14 HEPA/ULPA filter replacement beneath the working surface for service technicians and environment protection according to DIN 12980:2005-06 Standard.

ECS® Eco Controling System: The new ECS® microprocessor employs the latest innovative methods of integrated management of all principal functions of ventilation and filtration - self-regulating all the main filtration and ventilation system components - compensating for declining pressure drops and restoring power balance. Combining the use of AC motor-blowers and certified low pressure-drop filters, the new ECS® controlling system optimize power consumption, reducing CO2 emissions into the environment.

Anti Bacterial Coating: Exclusive Dupont™ ALESTA® anti-bacterial “Ag+ cations-based solution”, capable to prevent microbial contamination of surfaces thereby inhibiting long term surface growth.


Inflatable gasketing is also available as an option to provide effective sealing of the internal workspace of the chamber for purposes of fumigation/sterilization and when gas-tight is needed.

Silent Operation: The TNT plenum, the structures of the electric motors of the fans fitted on their antivibration mounts and the software itself designed to provide optimum air handling characteristics guarantee quiet operation of this silent safety cabinet, with sound-pressure levels recorded way below the parameters specified in the current EN:12469 European Standard for Microbiological Safety Cabinets.

Protection grid: A protection grid made of AISI 304L stainless steel is provided inside the part behind the rear panel (where air flows), in order to avoid the tissue used during cleaning operations be sucked in the motor-blower causing the failure of the blower and other damages.

High Level Lighting: The safety glass side-windows with the ideal positioning and sizing of the light-system provide the highest level of luminosity to the work area.

Easy handling and maintenance: The cabinet can pass through standard 800 mm wide door openings. In fact, the overall depth of the cabinet can be reduced to approx. 777 mm by removal of the rear panel. All service operations are available from the front of the cabinet. Despite the overall height, CytoFAST Elite have a demountable base stand of 255 mm. Without this stand the cabinet height is 1995 mm and can easily pass through doors of 2 meters height.

Automatic safety service connections for gas and vacuum and one (for size 209 and 212) or two (for size 215 and 218) electrical socket(s) fitted as standard in each size model.

External structure in epoxy powder coated cold-rolled steel for excellent corrosion resistance to the attack by aggressive common chemicals. Alternatively special models with external structure made in AISI 304L stainless steel for superior cleanability are also available on demand.

Rear wall in stainless steel AISI 304 L, designed to conform to requirements and pass the “cleanability test” according to EN12469:2000.

Work surface in stainless steel AISI 316L as standard supplied with spill retaining solid work surface (perforated upon request) which is easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures. Special sloping profile below work surface to ease H14 HEPA/ULPA filter replacement and spilled liquids collection.

Front window: electrically operated vertically sliding safety glass sash window.

Re-circulating and extractor fans: CytoFAST Elite are fitted with double motor-fan that are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system if required.

Filtration: H14 HEPA/ULPA filters with an efficiency better than 99,995 % MPPS (EN-1822). Third bank of class H14 HEPA/ULPA filters with easy replace system is positioned beneath work surface built for handling cytotoxic drugs.

Operation Condition: Air cleanliness in Class ISO 3 as per ISO:EN 14644-1.

The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:

• display of laminar airflow velocity and frontal air barrier velocity
• display of inside and outside temperature
• display of residual lifetime of HEPA/ULPA filters, UV Lamp and activated carbon filter (if fitted)
• display of total number of hours of operation
• display of saturation level of HEPA/ULPA filters.

Audio-visual alarms provided for:

• out of range or incorrect laminar airflow velocity and frontal air barrier velocity
• incorrect position of front sash-window
• clogging of HEPA/ULPA filters
• end of life-cycle of UV lamp and saturation of activated carbon filter (if fitted)
• blockage in the exhaust duct ( if fitted )
• fan-motor malfunction
• power failure

Lighting: fluorescent tubes in built-in housing, placed outside the contaminated area

D.O.P.-DEHS inlet port for testing the HEPA/ULPA filters

Magnetic and removable UV sterilizing lamp (optional) that can be easily placed in each area of the back wall. It is completed with two switch-off countdown timers, one variable on a 0-3 hours scale (1 minute steps), the other set to 3 fixed hours.




Product Code Width [cm] Pressure Motor-blowers
CytoFAST Elite 209 F000211A0000 90 Negative Double fan

Technical sheet

Useful dimension (mm)::WxDxH: 887x580x740
Overall dimension [mm]: WxDxH: 1045x855x2345(*)
Noise level (dbA): <53
Working Aperture (mm): 200
Exhaust flow rate (m3/h): 290
Lighting level (lux): >1100
Weight (kg): 215
Electrical data [230V - 50H] (**): 230 V - 50 Hz
Current consumption (A): 2,3
Heat emission (W): 175
(*) overall depth can be reduced to <800mm to pass through any door/aisle:
(**) different voltage/frequency available upon request:

Accessories

FX0002124600 - UV Lamp for 0.9/1.2 mt size
FX0021449900 - Additional electrical socket
FX0002124710 - Additional Vacuum Tap
FX0021247200 - Additional Compressed Air Tap
FX0021247300 - Additional Nitrogen Tap
FX0021247400 - Additional Water Tap
FX0002124930 - Additional socket for data (RS232)
FX0002124920 - Additional socket for data (RS485)
FX0002124950 - Additional socket for data (RJ45)
FX0021450200 - Additional socket for data (USB)
FX0021144300 - Filter cover to enable the installation of perforated work surface in CF Elite 209
FX0021141100 - Replacement of HEPA filters under the work surface with activated charcoal filters in CF Elite 209, factory fitted
FX0002094030 - Exhaust charcoal filter without collar for 0.9 mt size
FX0002094020 - Additional exhaust HEPA filter without collar for 0.9 mt size
FX0002124940 - Volt free contact
FX0002124800 - Anti-blowback valve
A00XBBB54 - Touch screen controls
FX0002094040 - Exhaust hard duct connection 0.9 mt size
FX0002094070 - Exhaust thimble connection 0.9 mt size
FX0002124200 - Arm rests (couple)
FX0002094220 - Stainless steel bar for bags with 6 hooks for CytoFAST Elite 209
FX0021143400 - Kit to modify the CF Elite 209 as powder weighing station with solid work surface
A00XBBB51 - Adjustable electrical stand (stroke 700-1000mm) for 0.9 mt size
CytoFAST Elite 212 F000214A0000 120 Negative Double fan

Technical sheet

Useful dimension (mm)::WxDxH: 1192x580x740
Overall dimension [mm]: WxDxH: 1350x855x2345 (*)
Noise level (dbA): <54
Working Aperture (mm): 200
Exhaust flow rate (m3/h): 390
Lighting level (lux): >1200
Weight (kg): 245
Electrical data [230V - 50H] (**): 230 V - 50 Hz
Current consumption (A): 3
Heat emission (W): 240
(*) overall depth can be reduced to <800mm to pass through any door/aisle:
(**) different voltage/frequency available upon request:

Accessories

FX0002124600 - UV Lamp for 0.9/1.2 mt size
FX0021449900 - Additional electrical socket
FX0002124710 - Additional Vacuum Tap
FX0021247200 - Additional Compressed Air Tap
FX0021247300 - Additional Nitrogen Tap
FX0021247400 - Additional Water Tap
FX0002124930 - Additional socket for data (RS232)
FX0002124920 - Additional socket for data (RS485)
FX0002124950 - Additional socket for data (RJ45)
FX0021450200 - Additional socket for data (USB)
FX0021444300 - Filter cover to enable the installation of perforated work surface in CF Elite 212
FX0021441100 - Replacement of HEPA filters under the work surface with activated charcoal filters in CF Elite 212, factory fitted
FX0002124030 - Exhaust charcoal filter without collar for 1.2 mt size
FX0002124020 - Additional exhaust HEPA filter without collar for 1.2 mt size
FX0002124940 - Volt free contact
FX0002124800 - Anti-blowback valve
A00XBBB54 - Touch screen controls
FX0002124040 - Exhaust hard duct connection 1.2 mt size
FX0002124070 - Exhaust thimble connection 1.2 mt size
FX0002124200 - Arm rests (couple)
FX0002124220 - Stainless steel bar for bags with 6 hooks for CytoFAST Elite 212
FX0021443400 - Kit to modify the CF Elite 212 as powder weighing station with solid work surface
FS0000000120 - Adjustable electrical stand (stroke 700-1000mm) for 1.2 mt size
CytoFAST Elite 215 F000217A0000 150 Negative Double fan

Technical sheet

Useful dimension (mm)::WxDxH: 1497x580x740
Overall dimension [mm]: WxDxH: 1655x855x2345 (*)
Noise level (dbA): <55
Working Aperture (mm): 200
Exhaust flow rate (m3/h): 485
Lighting level (lux): >1200
Weight (kg): 285
Electrical data [230V - 50H] (**): 230 V - 50 Hz
Current consumption (A): 3,6
Heat emission (W): 280
(*) overall depth can be reduced to <800mm to pass through any door/aisle:
(**) different voltage/frequency available upon request:

Accessories

FX0002154600 - UV Lamp for 1.5/1.8 mt size
FX0021449900 - Additional electrical socket
FX0002124710 - Additional Vacuum Tap
FX0021247200 - Additional Compressed Air Tap
FX0021247300 - Additional Nitrogen Tap
FX0021247400 - Additional Water Tap
FX0002124930 - Additional socket for data (RS232)
FX0002124920 - Additional socket for data (RS485)
FX0002124950 - Additional socket for data (RJ45)
FX0021450200 - Additional socket for data (USB)
FX0021744300 - Filter cover to enable the installation of perforated work surface in CF Elite 215
FX0021741100 - Replacement of HEPA filters under the work surface with activated charcoal filters in CF Elite 215, factory fitted
FX0002154030 - Exhaust charcoal filter without collar for 1.5 mt size
FX0002154020 - Additional exhaust HEPA filter without collar for 1.5 mt size
FX0002124940 - Volt free contact
FX0002124800 - Anti-blowback valve
A00XBBB54 - Touch screen controls
FX0002154040 - Exhaust hard duct connection 1.5 mt size
FX0002154070 - Exhaust thimble connection 1.5 mt size
FX0002124200 - Arm rests (couple)
FX0002154220 - Stainless steel bar for bags with 6 hooks for CytoFAST Elite 215
FX0021743400 - Kit to modify the CF Elite 215 as powder weighing station with solid work surface
A00XBBB52 - Adjustable electrical stand (stroke 700-1000mm) for 1.5 mt size
CytoFAST Elite 218 F000220A0000 180 Negative Double fan

Technical sheet

Useful dimension (mm)::WxDxH: 1802x580x740
Overall dimension [mm]: WxDxH: 1960x855x2345 (*)
Noise level (dbA): <56
Working Aperture (mm): 200
Exhaust flow rate (m3/h): 585
Lighting level (lux): >1300
Weight (kg): 325
Electrical data [230V - 50H] (**): 230 V - 50 Hz
Current consumption (A): 4,5
Heat emission (W): 360
(*) overall depth can be reduced to <800mm to pass through any door/aisle:
(**) different voltage/frequency available upon request:

Accessories

FX0002154600 - UV Lamp for 1.5/1.8 mt size
FX0021449900 - Additional electrical socket
FX0002124710 - Additional Vacuum Tap
FX0021247200 - Additional Compressed Air Tap
FX0021247300 - Additional Nitrogen Tap
FX0021247400 - Additional Water Tap
FX0002124930 - Additional socket for data (RS232)
FX0002124920 - Additional socket for data (RS485)
FX0002124950 - Additional socket for data (RJ45)
FX0021450200 - Additional socket for data (USB)
FX0022044300 - Filter cover to enable the installation of perforated work surface in CF Elite 218
FX0022041100 - Replacement of HEPA filters under the work surface with activated charcoal filters in CF Elite 218, factory fitted.
FX0002184030 - Exhaust charcoal filter without collar for 1.8 mt size
FX0002184020 - Additional exhaust HEPA filter without collar for 1.8 mt size
FX0002124940 - Volt free contact
FX0002124800 - Anti-blowback valve
A00XBBB54 - Touch screen controls
FX0002184040 - Exhaust hard duct connection 1.8 mt size
FX0002184070 - Exhaust thimble connection 1.8 mt size
FX0002124200 - Arm rests (couple)
FX0002184220 - Stainless steel bar for bags with 6 hooks for CytoFAST Elite 218
FX0022043400 - Kit to modify the CF Elite 218 as powder weighing station with solid work surface
FS0000000204 - Adjustable electrical stand (stroke 700-1000mm) for 1.8 mt size